Specifications

Product Name Anesthesia Machine
Model Anaeston 5000L
Dimension 810x860x1360 mm (WxDxH )
Weight 110 kg
Anesthetic type Halothane, Enflurane , Isoflurane , Sevoflurane , Desflurane
Gas supply O2+N2O, or O2+N2O+Air
Input pressure 280~650 kpa (350~400kpa is recommended)
Standard vent. mode VCV, PCV, PLV, PSV, SIMV+VCV+PS, SIMV+PCV+PS
Display screen 12.1″ color
Value display (Set and measured) Tidal volume, minute volume, respiratory rate, I:E ratio, pressure limit
Airway pressure (Ppeak , Pmean , Pmax , Pplateau , PEEP)
FiO2%, Compliance (ml/cmH2O)
Pressure support level, Inspiratory Window, P-trigger, Inspiratory End
EtCO2 and InCO2 (optional)
CSI, BS%, SQI%, EMG% (Optional)
Graphic display P-T, F-T, V-T waveforms
P-V, P-F, F-V loops (for compliance, resistance, leakage analysis)
EtCO2 waveforms (when optional EtCO2 module is present)
CSI, BS%, SQI, EMG waveforms (when optional CSM is present)
Optional expansion Auxiliary Common Gas Outlet(ACGO)
Auxiliary O2 Gas Outlet
Suction System
Anesthetic gas scavenging system (AGSS)
EtCO2 (mainstream/sidestream ) module
CSM module (anesthetic depth and trend)
Anesthetic information management system
External patient monitor
Other equipment
Dimension 114x60x31 mm
Weight 130g with battery
Display size 32×17 mm
Classification Internal power supply/ Class II, Type BF, continuous use
Memory Data recording 18 hours
Digital output Wireless to RS232 link (ISM 2.4 GHz)
Wireless range Up to 10 meters
Work condition Temperature 10–40°C/50–104°F
Rel. humidity 30–75%
Air pressure 700–1060 hPa
Battery 9V Alkaline or rechargeable NiMH (6AM6/IEC:6LR61/ ANSI:1604A)
Supply current 25mA (typical)
Battery lifetime Alkaline 32h (stand-alone) 18h (transmitting wireless)
Battery lifetime Rechargeable 12h (stand-alone) 8h (transmitting wireless)
Alarms with user-selectable CSI high/low limit
Artifact rejection Automatic
Sensor impedance range 0-10kOhm / measurement current 0.01μA
EEG sensitivity ±400μV
Noise < 2μVp-p, < 0.4μV RMS, 1–250 Hz
CMR >140dB
Input impedance >50MOhm
Sample rate 2000 samples/sec. (14 bits equivalent)
CSI and update 0-100. Filter 6-42 Hz, 1 sec. update
EMG 0-100 logarithmic. Filter 75-85 Hz, 1 sec. update
BS% 0-100%. Filter 2-42 Hz, 1 sec. update

You may also like…